Pre-summer servicing is open. Every visit booked this season leaves with a written report and a dated next-service reminder.

Ask for a window
Cedar WorksAircon Servicing Get a quote
Service technician in a hard hat and high-visibility vest working on site

Cleaning · checks · written reports

Aircon that gets used hard needs servicing to match.

Cedar Works services wall splits, ceiling cassettes, window units and ducted systems across the inner suburbs. We measure first, clean properly, and tell you in writing what we found.

  • Measured, not guessedTemperature split, suction pressure and current draw recorded before any cleaning starts.
  • One visit, one reportYou get the readings, the work done and the next service date before we leave.
  • Repairs quoted, never assumedIf a system is losing refrigerant we find the leak instead of topping it up.

What we service

Four systems, four different jobs

A cassette and a window unit have almost nothing in common once the cover is off. Pick the lane that matches your system so the quote reflects the actual work.

Wall-mounted split units

The common household system. Most complaints come from a loaded filter and a biofilm-coated barrel fan rather than anything mechanical.

  • Filter wash and dryIncluded
  • Barrel fan and tray cleanIncluded
  • Drain line flush and fall checkIncluded
  • Indoor coil rinseWhere accessible
  • Typical time per unit60–90 min

Not included: refrigerant charging on a system that is losing gas. We locate the leak and quote the repair first.

Ceiling cassette units

Shops, studios and open-plan rooms. These hide their problems above the ceiling line, so the condensate pump and the blade seals matter most.

  • Grille removal and washIncluded
  • Turbine fan cleanIncluded
  • Condensate pump testIncluded
  • Blade motor and seal checkIncluded
  • Typical time per unit90–120 min

Access note: we need roughly two metres of clear floor beneath the unit and will bring our own platform.

Window and portable units

Often written off too early. A bench clean plus new seals usually restores most of the cooling these units had when new.

  • Full bench cleanIncluded
  • Foam and brush seal renewalIncluded
  • Exhaust hose and vent checkPortables
  • Tray and drain clearIncluded
  • Typical time per unit45–60 min

Worth knowing: if the compressor is tired we will say so rather than charge for a clean that will not help.

Ducted systems

One fault here affects every room. We work from the return air filter outward and check that each zone still does what the controller says it does.

  • Return air filter serviceIncluded
  • Supply grille vacuumAll rooms
  • Zone motor and damper checkIncluded
  • Static pressure readingIncluded
  • Typical time per system2–3 hours

Not included: duct replacement or ceiling work. If we find crushed or disconnected duct you get photographs and a separate quote.

Servicing intervals

How often a unit actually needs attention

Service intervals depend on how many hours the unit runs and how much dust the room carries — not on the calendar. These are the intervals we recommend to customers before they book.

Recommended intervals by room use
Room and use Filter wash Full clean Drain and coil check
Bedroom, overnight use Every 6 weeks Every 12 months Yearly
Living room, evenings and weekends Every 4 weeks Every 9 months Yearly
Home office, daytime hours Every 4 weeks Every 9 months Yearly
Rented unit, between tenancies At changeover At changeover At changeover
Shop or studio, trading hours Every 3 weeks Every 6 months Twice yearly

Fault index

What the symptom usually means

Six things customers describe on the phone most often, what tends to be behind them, and what we do about it on the visit.

It runs all evening and the room never gets cool

Usual cause

Restricted airflow from a loaded filter or a dirty indoor coil, so the unit moves plenty of air but barely cools it. The second most common cause is a slow refrigerant loss over a season or two.

What we do

Measure the temperature difference across the coil and read suction pressure before cleaning anything. If the split recovers after the clean, nothing else is needed. If it does not, the system is being tested for leaks, not topped up.

Water drips from the indoor unit

Usual cause

A blocked or back-pitched drain line, a cracked condensate tray, or ice forming on the coil and melting unevenly when the unit cycles off.

What we do

Flush the drain, check the fall along its whole run, and pressure-test for a partial block further down. If ice is the cause we treat the airflow or charge problem behind it rather than the drip itself.

It smells musty for the first ten minutes

Usual cause

Biofilm on the barrel fan and in the condensate tray. The smell appears on start-up because air passes over damp growth before the coil dries out.

What we do

Pull the barrel fan, clean it and the tray properly, then clear the drain so the tray empties fully. Spray-only treatments mask this for a fortnight; removing the growth is the repair.

It short-cycles — two minutes on, ten minutes off

Usual cause

A room sensor reading the return air instead of the room, a sensor drifting out of calibration, or a unit oversized for the space so it hits setpoint before the room is evenly cooled.

What we do

Compare the sensor reading against a calibrated thermometer at seated height, check the sensor position, and confirm the cycle time against the unit's own specification before suggesting anything is replaced.

The outdoor unit has become much louder

Usual cause

Debris against the fan blade, loose mounting feet transmitting vibration into the wall, a worn fan bearing, or a compressor labouring against a coil packed with lint and leaf litter.

What we do

Clear and rinse the condenser coil, retorque the mounts, isolate the noise with the fan running and the compressor stopped, and record the running current so a labouring compressor can be identified.

The remote shows a fault code and the unit stops

Usual cause

A protection cut-out doing its job: high head pressure from a blocked condenser, a failed sensor, or a drain float switch tripping because the tray cannot empty.

What we do

Read the code against the manufacturer's table, then test the circuit it points to. Send us the code when you enquire and we will arrive with the likely parts on the van.

How a visit runs

Four stages, start to report

A single-unit service takes about ninety minutes. Nothing is dismantled before it has been measured, and nothing leaves without being written down.

Walk the site

Every unit is logged: model, age, mount condition, drain route and the access we will need. You hear about anything that changes the quote before work starts.

Take readings

Temperature split, suction pressure, running current and drain fall, recorded while the system is still in the state you have been living with.

Clean and correct

Filters, barrel fan or turbine, tray, drain, coil and outdoor condenser. Covers come off, drop sheets go down, and the space is left as we found it.

Write it up

The same readings taken again, the work done, anything worth watching next season, and a dated next-service recommendation for each unit.

Request a quote

Tell us what you have and we will price the visit

We reply with a fixed price per unit, the time we will need, and the next two windows we can offer. No visit is booked until you have agreed the price.

  • The system type and roughly how many units — a photograph of the indoor unit tells us most of it.
  • Any fault code showing on the remote or wall controller.
  • Whether this is a first service or a repeat, and when it was last cleaned if you know.
  • For cassettes and ducted systems, how high the ceiling is and what sits beneath it.

We use these details to price the visit and nothing else.